Research Article
PSO–SOM Neural Network Algorithm for Series Arc Fault Detection
Table 3
Frequency domain feature values of lamp load circuit.
| Load name | Mean amplitude of fault current (%) | Mean amplitude of normal current (%) | Frequency range/Hz |
| Lamp | 3.7304 | 2.9273 | 0–200 | 0.9459 | 0.0210 | 200–400 | 0.5663 | 0.0911 | 400–600 | 0.4564 | 0.0758 | 600–800 | 0.2605 | 0.0204 | 800–1000 | 0.2916 | 0.0973 | 1000–1200 | 0.2300 | 0.0542 | 1200–1400 | 0.1797 | 0.0569 | 1400–1600 | 0.2215 | 0.0611 | 1600–1800 | 0.1782 | 0.0290 | 1800–2000 |
|
|