Research Article

PSO–SOM Neural Network Algorithm for Series Arc Fault Detection

Table 7

Load corresponding number in different working conditions.

Load typeWork stateCorresponding number

Lamp and inductor in seriesFault0010
Normal0011
LampFault0100
Normal0101
Induction cookerFault0110
Normal0111
ComputerFault1000
Normal1001
Hand drillFault1010
Normal1011