Research Article
An Improved Numerical Model of Shield Tunnel with Double Lining and Its Applications
Table 7
The axial force extreme values under different thicknesses of segment lining.
| Thickness of segment lining (cm) | 30 | 40 | 50 | 60 | 70 | Thickness of double lining (cm) | 60 | 70 | 80 | 90 | 100 | The increase ratio of double lining thickness | 100% | 117% | 133% | 150% | 167% | The section of maximum axial force of the double lining | | | | | | Axial force of double lining (MN) | −1.144 | −1.142 | −1.135 | −1.124 | −1.120 | Axial force of segment lining at the corresponding section (MN) | −0.744 | −0.789 | −0.819 | −0.845 | −0.875 | The allocation proportion of axial force of segment lining | 65% | 69% | 72% | 75% | 78% | The increase ratio of axial force of double lining | 100% | 99% | 99% | 98% | 98% | The section of minimum axial force of the double lining | | | | | | Axial force of double lining (MN) | −1.030 | −1.031 | −1.022 | −1.021 | −1.012 | Axial force of segment lining at the corresponding section (MN) | −0.669 | −0.715 | −0.744 | −0.778 | −0.797 | The allocation proportion of axial force of segment lining | 65% | 69% | 73% | 76% | 79% | The increase ratio of axial force of double lining | 100% | 99% | 99% | 99% | 98% |
|
|