The axial force extreme values under different thicknesses of segment lining.

Thickness of segment lining (cm)3040506070
Thickness of double lining (cm)60708090100
The increase ratio of double lining thickness100%117%133%150%167%
The section of maximum axial force of the double lining
 Axial force of double lining (MN)−1.144−1.142−1.135−1.124−1.120
 Axial force of segment lining at the corresponding section (MN)−0.744−0.789−0.819−0.845−0.875
 The allocation proportion of axial force of segment lining65%69%72%75%78%
 The increase ratio of axial force of double lining 100%99%99%98%98%
The section of minimum axial force of the double lining
 Axial force of double lining (MN)−1.030−1.031−1.022−1.021−1.012
 Axial force of segment lining at the corresponding section (MN)−0.669−0.715−0.744−0.778−0.797
 The allocation proportion of axial force of segment lining65%69%73%76%79%