Research Article
Pull-Out Resistance Capacity of a New Perfobond Shear Connector for Steel Pile Cap Strengthening
Table 4
Failure modes of test specimens.
| | 
 |  | Specimen | Failure characteristics | Ultimate failure mode |  | Concrete delamination and cracking
 | Yielding and fracture of the steel flat-plate shear connector
 | Pull-out of the perforated flat-plate
 |  | 
 |  | PN-0015-N | X | X | O | Type I |  | PO-5015-N | X | X | O | Type II |  | PO-6015-N | X | X | O |  | PO-4015-R | O | X | O | Type III |  | PO-5015-R | O | X | O |  | PO-6015-R | X | O | X | Type IV |  | PO-5027-N | X | O | X |  | PO-5027-R | X | O | X |  | PU-5027-N | X | O | X |  | PU-5027-R | O | O | O | Type V |  | 
 | 
 |