Field investigation data (Building 1, construction completion year: 1981).

Measurement pointMember typeConcrete compressive strength (MPa)Concrete carbonation depth (mm)Cover depth (mm)Crack width (mm)

B1P1Beam18.624.1886
B1P2Slab22.417.0767
B1P3Wall32.69.4450Finishing crack on surface
B1P4Slab20.619.7552
B1P5Beam17.78.8767
B1P6Column29.514.3367
B1P7Wall26.15.8149
B1P8Column24.715.6139
B1P9Slab23.89.9857
B1P10Beam28.49.9551
B1P11Slab28.65.6232
B1P12Beam35.310.7377
B1P13Wall36.65.0658
B1P14Wall30.25.04330.1
B1P15Wall37.75.3926
B1P16Wall25.929.95420.1
B1P17Slab26.110.1049Finishing crack on surface
B1P18Beam34.110.1478Finishing crack on surface
B1P19Slab37.410.8555Finishing crack on surface
B1P20Beam36.518.6665Finishing crack on surface