Advances in Materials Science and Engineering / 2016 / Article / Tab 3 / Research Article
Estimation of Concrete Carbonation Depth Considering Multiple Influencing Factors on the Deterioration of Durability for Reinforced Concrete Structures Table 3 Field investigation data (Building 1, construction completion year: 1981).
Measurement point Member type Concrete compressive strength (MPa) Concrete carbonation depth (mm) Cover depth (mm) Crack width (mm) B1P1 Beam 18.6 24.18 86 — B1P2 Slab 22.4 17.07 67 — B1P3 Wall 32.6 9.44 50 Finishing crack on surface B1P4 Slab 20.6 19.75 52 — B1P5 Beam 17.7 8.87 67 — B1P6 Column 29.5 14.33 67 — B1P7 Wall 26.1 5.81 49 — B1P8 Column 24.7 15.61 39 — B1P9 Slab 23.8 9.98 57 — B1P10 Beam 28.4 9.95 51 — B1P11 Slab 28.6 5.62 32 — B1P12 Beam 35.3 10.73 77 — B1P13 Wall 36.6 5.06 58 — B1P14 Wall 30.2 5.04 33 0.1 B1P15 Wall 37.7 5.39 26 — B1P16 Wall 25.9 29.95 42 0.1 B1P17 Slab 26.1 10.10 49 Finishing crack on surface B1P18 Beam 34.1 10.14 78 Finishing crack on surface B1P19 Slab 37.4 10.85 55 Finishing crack on surface B1P20 Beam 36.5 18.66 65 Finishing crack on surface