Research Article

Estimation of Concrete Carbonation Depth Considering Multiple Influencing Factors on the Deterioration of Durability for Reinforced Concrete Structures

Table 6

Field investigation data (Building 4, construction completion year: 1984).

Measurement pointMember typeConcrete compressive strength (MPa)Concrete carbonation depth (mm)Cover depth (mm)Crack width (mm)

B4P1Column32.220.3535
B4P2Column29.723.5635
B4P3Beam2917.920
B4P4Beam26.921.3560
B4P5Beam31.712.8970
B4P6Beam29.418.1830
B4P7Slab26.571.06440.2
B4P8Slab29.816.6935
B4P9Beam26.645.91600.5
B4P10Slab31.226.8250
B4P11Beam26.528.4920
B4P12Slab27.126.2940
B4P13Beam24.822.7430Surface finishing crack
B4P14Beam30.919.0935Surface finishing crack
B4P15Slab20.525.7435Surface finishing crack
B4P16Slab18.646.4220Surface finishing crack
B4P17Wall34.315.990
B4P18Wall28.914.655
B4P19Wall3211.2150
B4P20Wall34.415.2250