Measured maximum stress for static test.

Load caseLoad conditionsMaximum stress (MPa)Yielding strength (MPa)Safety factorMaterialGauge no.

1Vertical force−1273252.56SM490A02
1133252.87SM490A37
2Transverse force−1143252.85SM490A02
1043253.13SM490A38
3Longitudinal force953153.32STKM18A32
843253.86SM490A36
4Lozenging forces−873253.74SM490A02
5Twist load−933253.49SM490A42
6Traction motor−1063253.01SM490A10
Inertia load
7Traction motor load−933253.49SM490A01
8Emergency braking load−1073253.04SM490A02
9Active steering force1403152.25STKM18A32
Vertical + transverse force1233252.64SM490A34
Vertical + transverse + twist force1353252.41SM490A34

Combined load at normal service load.