Research Article

Fatigue Design Evaluation of Railway Bogie with Full-Scale Fatigue Test

Table 5

Comparison of fatigue damage between lab test and track test.

LocationFatigue testTrack testRemark

Point 11st load step0.070.02 Track test: in-service track
2nd load step0.20Distance/year: 2 × 105
3rd load step0.46Life: 30 years