Research Article

Mining-Induced Damage Characteristics of Floors during Fully Mechanized Caving Mining: A Case Study

Table 2

Failure and damage characteristics of the floor rocks at the buried locations of each probe sensor.

Mining faceProbe sensorBuried depth (m)Failure or notMutation typeFailure depth (m)

100502-8014.93YPull-pressure strain mutation12.5–14.65
27.93YAbnormal mutation
59.5YPull-pressure strain mutation
310.93YAbnormal mutation
612.5YPull-pressure strain mutation
414.65N
715.5N
817.5N
919.5N

100502-1801012.2YPull-pressure strain mutation17.5–19.2
1513.5YPull-pressure strain mutation
1115.2YPull-pressure strain mutation
1217.2Probe damaged
1617.5YPull-pressure strain mutation
1319.2N
1720N
1422N