Research Article
Mining-Induced Damage Characteristics of Floors during Fully Mechanized Caving Mining: A Case Study
Table 2
Failure and damage characteristics of the floor rocks at the buried locations of each probe sensor.
| Mining face | Probe sensor | Buried depth (m) | Failure or not | Mutation type | Failure depth (m) |
| 100502-80 | 1 | 4.93 | Y | Pull-pressure strain mutation | 12.5–14.65 | 2 | 7.93 | Y | Abnormal mutation | 5 | 9.5 | Y | Pull-pressure strain mutation | 3 | 10.93 | Y | Abnormal mutation | 6 | 12.5 | Y | Pull-pressure strain mutation | 4 | 14.65 | N | — | 7 | 15.5 | N | — | 8 | 17.5 | N | — | 9 | 19.5 | N | — |
| 100502-180 | 10 | 12.2 | Y | Pull-pressure strain mutation | 17.5–19.2 | 15 | 13.5 | Y | Pull-pressure strain mutation | 11 | 15.2 | Y | Pull-pressure strain mutation | 12 | 17.2 | Probe damaged | — | 16 | 17.5 | Y | Pull-pressure strain mutation | 13 | 19.2 | N | — | 17 | 20 | N | — | 14 | 22 | N | — |
|
|