Research Article

Experimental Study on the Mechanical Properties of Amorphous Alloy Fiber-Reinforced Concrete

Table 7

Result of flexural strength tests.

Mixture no.Fiber length (mm)Vf (%)Flexural strength (MPa)
7 d28 d90 d
Measured (MPa)Strength-effectiveness (%)Measured (MPa)Strength-effectiveness (%)Measured (MPa)Strength-effectiveness (%)

C004.01 (±0.23)4.63 (±0.16)5.74 (±0.35)

SF1350.24.25 (±0.19)6.124.87 (±0.21)5.215.97 (±0.43)4.15
SF20.44.34 (±0.26)8.314.98 (±0.37)7.566.12 (±0.58)6.65
SF30.64.42 (±0.26)10.225.05 (±0.32)9.236.21 (±0.45)8.18
SF40.84.59 (±0.32)14.475.19 (±0.34)12.216.30 (±0.51)9.86
SF51.04.71 (±0.27)17.455.28 (±0.45)14.156.40 (±0.69)11.56

AF1350.24.82 (±0.34)20.325.47 (±0.35)18.126.65 (±0.50)15.87
AF20.45.21 (±0.31)29.855.91 (±0.48)27.547.15 (±0.70)24.65
AF30.65.54 (±0.43)38.146.33 (±0.52)36.787.47 (±0.77)30.12
AF40.85.74 (±0.39)43.216.49 (±0.53)40.217.79 (±0.63)35.78
AF51.05.90 (±0.50)47.216.72 (±0.65)45.217.93 (±0.75)38.21