Research Article
A Parameter Ascertainment Method for the Skeleton Curve of Corroded Reinforcement Concrete Members with Flexure and Compression
Table 3
The comparison between theoretical value and experimental value.
| | 
 |  | Number of specimens | Axial compression ratio | Corrosion rate (%) | Experimental value (Fyd/kN) | Calculation value (Fyd/kN) | Ratio | Experimental value (Xyd/mm) | Calculation value (Xyd/mm) | Ratio |  | 
 |  | ZZ-1 | 0.27 | 0 | 41.78 | 47.70 | 1.14 | 9.32 | 10.37 | 1.11 |  | Z-2 | 0.27 | 20 | 38.51 | 37.24 | 0.97 | 7.08 | 9.81 | 1.39 |  | Z-3 | 0.27 | 18 | 37.11 | 38.06 | 1.03 | 7.85 | 9.87 | 1.26 |  | Z-4 | 0.27 | 18 | 36.31 | 38.06 | 1.05 | 6.79 | 9.87 | 1.45 |  | Z-5 | 0.27 | 23 | 31.34 | 33.72 | 1.08 | 8.03 | 9.52 | 1.19 |  | Z-6 | 0.27 | 6 | 41.15 | 44.91 | 1.09 | 9.36 | 10.27 | 1.09 |  | Z-7 | 0.27 | 25 | 36.89 | 32.96 | 0.89 | 9.03 | 9.44 | 1.05 |  | 
 | 
 | 
| Note: ratio = calculation value/experimental value, the ratio in the following table are calculated according to this definition.
 |