Research Article
A Parameter Ascertainment Method for the Skeleton Curve of Corroded Reinforcement Concrete Members with Flexure and Compression
Table 7
The comparison between theoretical value and experimental value.
| | 
 |  | Number of specimens | Axial compression ratio | Corrosion rate (%) | Experimental value (Fyd/kN) | Calculation value (Fyd/kN) | Ratio | Experimental value (Xyd/mm) | Calculation value (Xyd/mm) | Ratio |  | 
 |  | XZ-7 | 0.2 | 4.06 | 38.43 | 42.66 | 1.11 | 13.42 | 9.68 | 0.72 |  | XZ-8 | 0.2 | 5.87 | 36.08 | 41.89 | 1.16 | 10.12 | 9.64 | 0.95 |  | XZ-9 | 0.2 | 6.56 | 35.94 | 41.59 | 1.16 | 9.91 | 9.63 | 0.97 |  | XZ-5 | 0.4 | 4.23 | 44.45 | 51.15 | 1.15 | 12.04 | 11.36 | 0.94 |  | XZ-10 | 0.4 | 5.87 | 46.31 | 50.44 | 1.09 | 10.77 | 14.16 | 1.31 |  | XZ-1 | 0.4 | 7.64 | 42.05 | 49.68 | 1.18 | 10.84 | 13.62 | 1.25 |  | 
 | 
 |