Research Article
Utilization of Local Ingredients for the Production of High-Early-Strength Engineered Cementitious Composites
Table 3
Mix design of domestic ECCs (weight ratios).
| Mix ID | Cement | Silica fume | Silica flour | Silica sand | Water | Super plasticizer | Fiber (by volume) |
| ECC1 | 1 | 0.18 | 0.18 | 0.74 | 0.39 | 0.02 | 2% (REC-15 PVA) | ECC2 | 1 | 0.18 | 0.18 | 0.74 | 0.39 | 0.02 | 2% (BHL PVA) | ECC3 | 1 | 0.18 | 0.18 | 0.74 | 0.39 | 0.02 | 0.5% (PE) | ECC4 | 1 | 0.18 | 0.18 | 0.74 | 0.39 | 0.02 | 0.8% (PE) |
|
|