Experimental Characterization of Traditional Mortars and Polyurethane Foams in Masonry Wall

Table 5

Results of vertical compression tests.

Test of vertical compression on blocks
BrickBinderMaximum load (KN)Compressive strength (N/mm2)

Specimen 1 (thin joint)Module FV “MVI350” (35 × 25 × 24.5 cm)Polyurethane foam4805.714
Specimen 2 (thin joint)Module FV “MVI350” (35 × 25 × 24.5 cm)Polyurethane foam4305.119
Specimen 3 (ordinary joint)Iper (30 × 24 × 24 cm)M1-mortar741.358.513
Specimen 4 (thin joint)Iper (30 × 24 × 24 cm)M1-mortar818.69.40
Specimen 5 (super-thin joint)Iper (30 × 24 × 24 cm)M1-mortar751.378.629
Specimen 6 (ordinary joint)Iper (30 × 24 × 24 cm)M2-mortar1098.512.615
Specimen 7 (thin joint)Iper (30 × 24 × 24 cm)M2-mortar1235.6214.19
Specimen 8 (Giunto Supersottile)Iper (30 × 24 × 24 cm)M2-mortar1125.0512.92