Research Article
Experimental Characterization of Traditional Mortars and Polyurethane Foams in Masonry Wall
Table 6
Results of the sliding on triplet tests.
| | Test of sliding on triplets | Brick | Binder | Maximum load (KN) | Shear strength (N/mm2) |
| Specimen 1 | Module FV “MVI350” (35 × 25 × 24.5 cm) | Polyurethane foam | 17.236 | 0.102 | Specimen 2 | Module FV “MVI350” (35 × 25 × 24.5 cm) | Polyurethane foam | 14.802 | 0.0881 | Specimen 3 | Porotherm Bio Plan (38 × 25 × 21.9 cm) | M3-mortar | 55.5 | 0.274 | Specimen 4 | Porotherm Bio Plan (38 × 25 × 21.9 cm) | M3-mortar | 58.1 | 0.283 | Specimen 5 | Porotherm Bio Plan (38 × 25 × 21.9 cm) | M3-mortar | 57.8 | 0.283 | Specimen 6 | Porotherm Bio Plan (38 × 25 × 21.9 cm) | M3-mortar | 45.8 | 0.223 | Specimen 7 | Porotherm Bio Plan (38 × 25 × 21.9 cm) | M3-mortar | 50.6 | 0.248 | Specimen 8 | Porotherm Bio Plan (38 × 25 × 21.9 cm) | M3-mortar | 54.9 | 0.265 |
|
|