Research Article
Molecular Sieving Film Prepared by Vacuum Filtration for the Efficient Removal of Tetracycline Antibiotics from Pharmaceutical Wastewater
Table 5
Comparison of adsorption parameters.
| Sample | Single cycle time (min) | Recycle times | Average vacuum (MPa) | Max. removal rate (%) | Total time (min) | Flux (L·m−2·h−1·bar−1) |
| Blank film | 1.25 | 15 | 0.060 | 39 | 18.75 | 3933.14 | PEI film | 1.52 | 15 | 0.062 | 35 | 22.80 | 3234.49 | ZIF-8/GO film-10 mg | 2.90 | 15 | 0.060 | 67 | 43.50 | 1695.32 | ZIF-8/GO film-20 mg | 4.25 | 15 | 0.060 | 85 | 63.75 | 1156.81 | ZIF-8/GO film-30 mg | 5.40 | 15 | 0.060 | 88 | 81 | 910.45 | ZIF-8/GO film-40 mg | 7.77 | 15 | 0.062 | 94 | 116.55 | 632.74 | ZIF-8/GO film-50 mg | 9.38 | 15 | 0.066 | 99 | 140.70 | 524.14 | 2D ZIF-8/GO hybrid nanosheets-50 mg | — | — | — | 96 | 500 | — |
|
|