Design of tests based on CCD and test results.

RunDesign of testsResults of tests
ABCSP (% of binder)Slump flow (mm)VSI

11.0001.0001.0000.7024400
2−1.0001.0001.0000.5264200
30.0000.0000.0000.5214500
40.0001.6820.0000.6674300
5−1.6820.0000.0000.2814300
61.000−1.000−1.0000.0754701
70.0000.0001.6821.2534200
80.0000.000−1.6820.0005402
90.0000.0000.0000.5214600
100.000−1.6820.0000.5964600
110.0000.0000.0000.5214450
120.0000.0000.0000.5214500
13−1.000−1.0001.0001.0034650
141.000−1.0001.0001.0534600
15−1.0001.000−1.0000.3514751
161.0001.000−1.0000.2515001
17−1.000−1.000−1.0000.0004401
181.6820.0000.0000.6024500
190.0000.0000.0000.5214500
200.0000.0000.0000.5214450