Research Article

Crack Resistance Properties of HPFRC Beam-Column Joints under Cyclic Load

Table 4

Comparison of HPFRC joint cracking strength between calculated values and experimental values.

SpecimenLoading directionExperiment values ( (kN))Calculated values ( (kN))SpecimenLoading directionExperiment values ( (kN))Calculated values ( (kN))

EJ-1Positive139.13144.170.965J-1Positive156.52162.110.966
Negative156.52144.171.086Negative175.31162.111.081
EJ-2Positive156.52117.081.337J-2Positive187.83162.111.159
Negative113.04117.080.966Negative156.52162.110.966
EJ-3Positive125.22129.750.965J-3Positive187.83194.540.965
Negative173.91129.751.340Negative187.83194.540.965
EJ-4Positive173.91180.210.965J-4Positive219.13194.541.126
Negative191.30180.211.062Negative187.83194.540.965
EJ-5Positive121.74126.150.965LJ-1Positive338.79350.890.966
Negative139.13126.151.103Negative338.79350.890.966
EJ-6Positive156.52162.190.965LJ-2Positive254.09296.070.858
Negative173.91162.191.072Negative296.44296.071.001
EJ-7Positive139.13144.170.965LJ-3Positive296.44307.030.966
Negative156.52144.171.086Negative338.79307.031.103
EJ-8Positive142.61147.700.966LJ-4Positive337.66349.720.966
Negative149.57147.701.013Negative337.66349.720.966
EJ-9Positive121.74126.090.966LJ-5Positive337.66349.720.966
Negative173.91126.091.379Negative337.66349.720.966
EJ-10Positive191.30180.121.062LJ-6Positive296.44307.030.966
Negative173.91180.120.966Negative338.79307.031.103
EJ-H1Positive121.74126.090.966LJ-7Positive338.79348.540.972
Negative139.13126.091.103Negative381.14348.541.094
EJ-H2Positive149.57148.711.006LJ-8Positive295.45306.000.966
Negative156.52148.711.053Negative337.66306.001.103