Research Article

Model Test on Bearing Characteristics of Basalt Fiber-Reinforced Concrete Lining

Table 3

Test results of flexural strength.

TypeAverage bending strength (MPa)Size conversion factorConversion strength (MPa)Growth ratio

Plain concrete3.0420.852.5861
Basalt fiber-reinforced concrete3.5710.853.0351.174