Research Article
Investigation on Deicing Property of Steel Wool Fiber-Reinforced Asphalt Mixture by Induction Heating
Table 1
Technical properties of SK-90# asphalt binder.
| Material | Test items | Unit | Value | Specification |
| Matrix asphalt binder | Penetration at 25°C | 0.1 mm | 86 | ASTM D5-97 | Ductility at 15°C | Cm | 182 | ASTM D113-99 | Softening point | °C | 47.0 | ASTM D36-06 | Wax content | % | 1.75 | ASTM D3344-90 | Flash point | °C | 304 | ASTM D92-02 | Specific gravity | Non | 1.030 | ASTM D70-76 | RTFO binder | Mass loss | % | 0.15 | ASTM D2872-04 | Penetration ratio at 25°C | % | 60.5 | ASTM D5-97 | Ductility at 10°C | cm | 9.8 | ASTM D113-99 |
|
|
Rolling thin film oven (RTFO) aged, according to ASTM D2872-04. |