Table 4
Comparison between melting temperature of oxides and duplex stainless steel.
| Oxides | Melting point (°C) | Melting point of DSS 2205 (°C) | ΔT = |Tm 2205 − Tm oxide| | Binary fluxes |
| Fe2O3 | 1565 | 1445 | 120°C (Tm oxide is higher than Tm 2205) | Fe2O3-Cr2O3 | Cr2O3 | 2335 | 890°C (Tm oxide is higher than Tm 2205) | ZnO | 1975 | 530°C (Tm oxide higher than Tm 2205) | ZnO-Mn2O3 | Mn2O3 | 940 | 505°C (Tm oxide less than Tm 2205) | V2O5 | 670 | 775°C (Tm oxide less than Tm 2205) | V2O5-Mn2O3 | Mn2O3 | 940 | 505°C (Tm oxide less than Tm 2205) |
|
|