Research Article
Thermal Performance Analysis of Low-GWP Refrigerants in Automotive Air-Conditioning System
Table 2
Uncertainties of the measuring instruments and calculated parameters.
| Item | Uncertainty (%) |
| Thermocouples (type-k) | ±2.1 | Hotwire anemometer | ±3.3 | Refrigerant flowmeter | ±2.9 | Refrigerant pressure gauge | ±3 | Refrigeration capacity | ±6.3 | Compressor power | ±7.2 | COP | ±5.6 | Heat rejection | ±7.3 | Total energy destruction | ±7.9 |
|
|