Research Article

Thermal Performance Analysis of Low-GWP Refrigerants in Automotive Air-Conditioning System

Table 3

Results of the investigated refrigerants at different condensing temperatures.

ItemTc, oCR152aR1234yfR1234ze(E)R134a

Cooling capacity306.606.695.616.90
356.446.385.386.65
406.246.065.156.39
456.045.734.916.12

Compressor power301.581.691.251.71
351.7741.901.431.94
401.9842.111.602.15
452.1912.311.772.37

COP304.183.964.474.03
353.633.363.773.44
403.152.883.222.97
452.762.482.782.58

Total exergy destruction, Etotal300.5490.8510.8450.748
350.5300.8120.8210.730
400.5240.7800.8010.710
450.5320.7700.7970.701

Total exergy efficiency, ηtotal300.3220.280.3570.34
350.2990.260.3360.32
400.270.250.310.3
450.2550.240.290.28