Research Article

A Corrosion Detection Method for Steel Strands Based on LC Electromagnetic Resonance

Table 3

Test data of the first group of steel strands.

True rust rate (%)Average true rust rate (%)Resonant frequency (kHz)Average frequency (kHz)
Steel strands 1Steel strands 2Steel strands 3Steel strands 1Steel strands 2Steel strands 3

0000371.234370.263368.959370.152
2.062.112.132.1371.124372.532371.129371.595
4.013.984.164.05372.896373.124373.091373.037
6.336.456.426.4375.122374.864373.454374.48
7.927.937.947.93376.113376.023375.633375.923
10.3010.3710.3110.34377.210376.981377.904377.365
12.4512.7212.6312.6378.684379.022378.789378.808