Ф9 mm experimental data of aluminum strands.
| l/m | f1 (kHz) | f2 (kHz) | f3 (kHz) | f4 (kHz) | SD | RE (%) | f (kHz) |
| 6.0 | 104.612 | 104.625 | 104.606 | 104.608 | 0.0086 | 0.0182 | 104.613 | 6.5 | 103.273 | 103.277 | 103.262 | 103.281 | 0.0082 | 0.0184 | 103.273 | 7.0 | 101.836 | 101.847 | 101.864 | 101.856 | 0.0122 | 0.0278 | 101.851 | 7.5 | 101.166 | 101.179 | 101.191 | 101.196 | 0.0134 | 0.0296 | 101.183 | 8.0 | 100.815 | 100.784 | 100.787 | 100.794 | 0.0140 | 0.0308 | 100.795 | 10.0 | 98.421 | 98.363 | 98.465 | 98.397 | 0.0426 | 0.1030 | 98.411 | 10.5 | 97.621 | 97.666 | 97.643 | 97.633 | 0.0192 | 0.0464 | 97.641 | 11.0 | 97.009 | 97.014 | 97.018 | 96.994 | 0.0106 | 0.0247 | 97.009 | 11.5 | 96.350 | 96.326 | 96.339 | 96.365 | 0.0166 | 0.0405 | 96.345 | 12.0 | 95.704 | 95.707 | 95.719 | 95.705 | 0.0072 | 0.0164 | 95.709 | 12.5 | 94.965 | 94.938 | 94.934 | 94.951 | 0.0140 | 0.0326 | 94.947 | 14.0 | 94.186 | 94.199 | 94.171 | 94.184 | 0.0115 | 0.0297 | 94.185 | 14.5 | 93.541 | 93.566 | 93.542 | 93.547 | 0.0117 | 0.0267 | 93.549 | 15.0 | 93.219 | 93.228 | 93.210 | 93.222 | 0.0076 | 0.0197 | 93.220 | 15.5 | 92.676 | 92.680 | 92.665 | 92.676 | 0.0064 | 0.0158 | 92.674 | 16.0 | 92.480 | 92.448 | 92.492 | 92.465 | 0.0188 | 0.0469 | 92.471 |
|
|