Research Article

Study on the Main Factors of Frequency Variation of LC Resonant Prestress Detection Method

Table 4

Ф15.2 mm experimental data of strand length.

l/mf1 (kHz)f2 (kHz)f3 (kHz)f4 (kHz)SDRE (%)f (kHz)

6.0103.907103.909103.900103.9120.00510.0115103.907
6.5103.183103.183103.213103.2250.02140.0407103.201
7.0102.522102.536102.538102.5400.00820.0176102.534
7.5101.394101.395101.372101.3790.01130.0227101.385
8.0100.745100.734100.753100.7480.00800.0189100.745
10.098.67598.64198.65298.6480.01470.034598.654
10.597.48597.46297.50297.4790.01650.041097.482
11.097.28797.29397.28597.2830.00430.010397.287
11.596.64096.64396.64296.6350.00360.008396.640
12.095.77895.78495.77695.7740.00430.010495.778
12.595.48295.44695.44795.4850.02140.040995.465
14.094.15394.13994.16294.1580.01000.024494.153
14.593.70593.69893.69593.7140.00840.020393.703
15.093.13893.16493.12793.1230.01850.044093.138
15.592.49092.47692.51292.4700.01870.045492.487
16.092.21192.20292.20092.2230.01050.024992.209