Research Article

An Inverse Transient Nonmetallic Pipeline Leakage Diagnosis Method Based on Markov Quantitative Judgment

Table 2

The second test of X5 node leakage parameters under different pressures.

Inlet pressure (MPa)Flow difference (kg/s)Node pressure (MPa)Effective node leakage area (m2)Real leakage area (m2)Absolute error (m2)

0.30.00270.11.151 × 10−51.256 × 10−50.105 × 10−5
0.20.00310.11.32 × 10−51.256 × 10−50.064 × 10−5
0.10.00170.061.208 × 10−51.256 × 10−50.048 × 10−5