The third test of X5 node leakage parameters under different pressures.

Inlet pressure (MPa)Flow difference (kg/s)Node pressure (MPa)Effective node leakage area (m2)Real leakage area (m2)Absolute error (m2)

0.30.00320.121.137 × 10−51.256 × 10−50.119 × 10−5
0.20.00240.091.137 × 10−51.256 × 10−50.119 × 10−5
0.10.00120.041.279 × 10−51.256 × 10−50.023 × 10−5