Research Article

Study on Safety Performance of Building Finish Layer under Thermomechanical Coupling Condition

Table 3

Pull-out test strength data of different temperatures.

Drill diameter (mm)Anchor bolt diameter (mm)Anchorage depth (mm)Construction temperature (°C)Test temperature (°C)Average pull-out strength (kN)

10106020200.385
380.383
38380.386
−50.343