Research Article

A Numerical Approach on Waste Heat Recovery through Sidewall Heat-Exchanging in an Aluminum Electrolysis Cell

Table 2

Comparison of the measured temperature values and ANSYS simulation results.

PositionANSYS simulated temperature (°C)Measured temperature on the 2 kA cell (°C)

Average temperature of the heat exchanger385379 ± 2
Side shell
 Top46–5146 ± 2
 Middle56–6458 ± 2
 Bottom42–4645 ± 2
Cathode busbar101–124108 ± 2
Bottom of the cell7167 ± 2
Lower surface of the cathode block811817 ± 2