Table 4
Composite column specimens and test results.
| S. no | Percentage replacement of silica fume (%) | Thickness (mm) | Height (mm) | Diameter (mm) | Load carrying capacity (kN) |
| 1 | 0 | 1.5 | 300 | 75 | 335.5 | 2 | 10 | 1.5 | 300 | 75 | 360.38 | 3 | 0 | 1.5 | 500 | 75 | 301.55 | 4 | 10 | 1.5 | 500 | 75 | 332.42 | 5 | 0 | 2 | 300 | 75 | 386.25 | 6 | 10 | 2 | 300 | 75 | 416 | 7 | 0 | 2 | 500 | 75 | 382.66 | 8 | 10 | 2 | 500 | 75 | 403.18 |
|
|