Research Article
Axial Compressive Behavior of Steel Fiber-Reinforced Recycled Coarse Aggregate Concrete-Filled Short Circular Steel Columns
Table 1
Details of all specimens.
| Specimen no. | RCA (%) | SF (%) | RCA (kg·m−3) | SF (kg·m−3) | NCA (kg·m−3) | Sand (kg·m−3) | Cement (kg·m−3) | Water (kg·m−3) | Concrete strength grade | (MPa) |
| TS-1 | 0 | 0.9 | 0 | 70.7 | 1257 | 531 | 422 | 190 | C30 | 42.9 | TS-2 | 50 | 0.9 | 628.5 | 70.7 | 628.5 | 531 | 422 | 190 | C30 | 32.6 | TS-3 | 100 | 0.9 | 1257 | 70.7 | 0 | 531 | 422 | 190 | C30 | 29.8 | TS-4 | 50 | 0.6 | 628.5 | 47.1 | 628.5 | 531 | 422 | 190 | C30 | 28.6 | TS-5 | 50 | 1.2 | 628.5 | 94.2 | 628.5 | 531 | 422 | 190 | C30 | 35.5 | TS-6 | 100 | 0.6 | 1257 | 47.1 | 0 | 531 | 422 | 190 | C30 | 26.6 | TS-7 | 100 | 1.2 | 1257 | 94.2 | 0 | 531 | 422 | 190 | C30 | 34.2 | TS-8 | 50 | 0.9 | 621 | 70.7 | 621 | 640 | 328 | 190 | C20 | 24.9 | TS-9 | 50 | 0.9 | 642.5 | 70.7 | 642.5 | 475 | 500 | 190 | C40 | 37.1 | TS-10 | 100 | 0.9 | 1242 | 70.7 | 0 | 640 | 328 | 190 | C20 | 22.6 | TS-11 | 100 | 0.9 | 1285 | 70.7 | 0 | 475 | 500 | 190 | C40 | 34.7 | TS-12 | 0 | 0 | 0 | 0 | 1257 | 531 | 422 | 190 | C30 | 29.5 | TS-13 | 50 | 0 | 628.5 | 0 | 628.5 | 531 | 422 | 190 | C30 | 27.1 | TS-14 | 100 | 0 | 1257 | 0 | 0 | 531 | 422 | 190 | C30 | 25.8 |
|
|