Research Article

Improving Heat Exchange Performance of Massive Concrete Using Annular Finned Cooling Pipes

Table 3

Design geometric and thermal parameters of the concrete and pipe.

PropertiesConcreteAFCPCP

Geometric sizes (m)hc = 1.3D = 5.0 × 10−2
 = 5.0 × 10−3D = 5.0 × 10−2
lc = 2.3 = 5.0 × 10−3 = 5.0 × 10−3
 = 1.0 × 10−1lp = 2.3
dc = 1.3lp = 2.3lf = 2.1
lf = 2.1

Adiabatic temperature (K)T(t) = 52.9 × (1 − e-t)
Specific heat (J/kgK)970871871
Thermal conductivity (w/mK)1.28202.4202.4