Research Article
Influence of Structural Parameters of Shape Memory Alloy Corrugated Gaskets on the Contact Pressure of Bolted Flange Joints
| | | Factor | Average contact pressure (MPa) | | T (thickness) | H (height) | P (span) |
| | 1 | 1 | 1 | 1 | 540.77 | | 2 | 1 | 2 | 2 | 542.55 | | 3 | 1 | 3 | 3 | 601.4 | | 4 | 2 | 1 | 3 | 702.77 | | 5 | 2 | 2 | 1 | 705.44 | | 6 | 2 | 3 | 2 | 963.18 | | 7 | 3 | 1 | 2 | 902.16 | | 8 | 3 | 2 | 3 | 1112.52 | | 9 | 3 | 3 | 1 | 1245.36 | | K1 | 561.57 | 715.23 | 872.15 | | | K2 | 790.46 | 786.83 | 830.22 | | | K3 | 1086.68 | 936.64 | 736.33 | | | Range | 175.03 | 73.804 | 45.27 | |
|
|