Research Article
Mechanical and Thermal Properties of RCB Masonry Containing Three Rows of Holes
Table 8
Standard and design values of compressive and shear strengths of RCB masonries.
| Group | Block (MPa) | Mortar (MPa) | Compressive strength (MPa) | Shear strength (MPa) | Standard values | Design values | Standard value | Design value |
| A1 | 10.5 | 8.0 | 4.98 | 2.93 | 0.133 | 0.078 | A2 | 10.5 | 12.0 | 5.39 | 3.17 | 0.163 | 0.096 | A3 | 10.5 | 14.8 | 5.61 | 3.30 | 0.181 | 0.106 | B1 | 7.53 | 6.2 | 2.95 | 1.73 | 0.117 | 0.069 | B2 | 7.53 | 8.0 | 3.35 | 1.97 | 0.133 | 0.078 | B3 | 7.53 | 12.0 | 4.06 | 2.39 | 0.163 | 0.096 |
|
|