Research Article
Interfacial Bond Properties between Normal Strength Concrete and Epoxy Resin Concrete
Table 3
Details of three kinds of specimens.
| Specimen type | NSC shape and size (mm) | ERC shape and size (mm) | Interface area (mm2) |
| Direct tension | Rectangular 300 × 300 × 150 | Rectangular 150 × 300 × 100 | 150 × 300 | Push-out | Rectangular 300 × 300 × 150 | Rectangular 300 × 300 × 100 | 250 × 300 | Slant shear | Trapezoidal (50 + 350) × 300 × 150 | Rectangular 300 × 150 × 100 | 300 × 150 |
|
|