Research Article

Interfacial Bond Properties between Normal Strength Concrete and Epoxy Resin Concrete

Table 5

Experimental results in the direct tensile, push-out, and slant shear tests.

SamplesFailure modeft (MPa)τ (MPa)Mean (MPa)SD (MPa)COV (%)

Direct tensile test1II0.720.880.011.55
2II0.91
3II1.00

Push-out test1II1.891.820.010.45
2II1.71
3II1.86

Slant shear test1III4.095.205.0296.53
2II3.19
3III8.33