Flue gas enthalpy temperature table.

Temperature ()Theoretical smoke enthalpy Iy (kJ/m3)Air enthalpy Ik (kJ/m3)Flame tube outlet α″ = 1.1 Iy (kJ/m3)Smoke pipe outlet αpy = 1.1 Iy (kJ/m3)

15250222272272
50833738907907
1001666147718141814
1202007177621852185
2003372297136693669
3005123449155725572
4006923604375277527
4507847683685318531
5008771763095349534
6001066792541159211592
70012612109111370313703
80014599125931585815858
85015609134481695416954
90016619143021805018050
100018673160312027720277
110020760177882253922539
120022872195562482824828
130025012213502714727147
140027167231562948329483
150029344249713184131841
160031539268003421934219
170033753286343661736617
175034864295523781937819
180035974304703902139021
190038206323314144041440
200040451341814386943869