Research Article
Effects of Size, Section Pattern, and Material on the Tensile Performance of Filled Thin-Walled Tubes
Table 2
Increase in tensile stresses of circular and square tubes.
| | Circular hollow tubes(kN) | Circular tubes + internal support (kN) | Increase in tensile stress (%) | Square hollow tubes (kN) | Square tube + internal support (kN) | Increase in tensile stress (%) |
| 10 MPa | 1.76 | 1.85 | 5.11 | 1.76 | 1.75 | −0.57 | 50 MPa | 8.80 | 9.29 | 5.57 | 8.80 | 8.76 | −0.45 | 100 MPa | 17.60 | 18.62 | 5.80 | 17.60 | 17.52 | −0.45 | 150 MPa | 26.40 | 27.94 | 5.83 | 26.40 | 26.27 | −0.49 | 200 MPa | 35.19 | 37.28 | 5.94 | 35.19 | 35.02 | −0.48 | 220 MPa | 38.71 | 43.10 | 11.34 | 38.72 | 41.93 | 8.29 | 250 MPa | 43.99 | 49.05 | 11.50 | 44.00 | 47.70 | 8.41 | 300 MPa | 52.79 | 58.73 | 11.25 | 52.80 | 55.11 | 4.38 | 350 MPa | 61.58 | 68.41 | 11.09 | 61.59 | 62.19 | 0.97 | 400 MPa | 70.37 | 78.08 | 10.96 | 70.39 | 69.15 | −1.76 | 450 MPa | 79.16 | 87.75 | 10.85 | 79.19 | 76.25 | −3.71 | 500 MPa | 87.96 | 97.42 | 10.75 | 88.00 | 83.04 | −5.64 |
|
|