Research Article
Experimental Study on CFRP-Confined Circularized Concrete-Filled Square Steel Tube Short Columns
Table 3
Experimental results of specimens.
| Specimen | fc0 (MPa) | (MPa) | N (kN) |
| C20-0-0-1 | 20.7 | 45.82 | 488.0 | C20-0-1-2 | 20.7 | 45.82 | 542.7 | C20-5-1-3 | 20.7 | 45.82 | 650.5 | C20-5-2-4 | 20.7 | 45.82 | 765.0 | C20-10-1-5 | 20.7 | 45.82 | 760.0 | C20-10-2-6 | 20.7 | 45.82 | 875.6 | C20-15-1-7 | 20.7 | 45.82 | 800.4 | C20-15-2-8 | 20.7 | 45.82 | 1019.3 | C30-0-0-9 | 27.1 | 53.39 | 539.9 | C30-0-1-10 | 27.1 | 53.39 | 631.6 | C30-5-1-11 | 27.1 | 53.39 | 738.3 | C30-5-2-12 | 27.1 | 53.39 | 867.1 | C30-10-1-13 | 27.1 | 53.39 | 843.9 | C30-10-2-14 | 27.1 | 53.39 | 950.3 | C30-15-1-15 | 27.1 | 53.39 | 893.4 | C30-15-2-16 | 27.1 | 53.39 | 1069.8 |
|
|