Research Article

Experimental Study on CFRP-Confined Circularized Concrete-Filled Square Steel Tube Short Columns

Table 3

Experimental results of specimens.

Specimenfc0 (MPa) (MPa)N (kN)

C20-0-0-120.745.82488.0
C20-0-1-220.745.82542.7
C20-5-1-320.745.82650.5
C20-5-2-420.745.82765.0
C20-10-1-520.745.82760.0
C20-10-2-620.745.82875.6
C20-15-1-720.745.82800.4
C20-15-2-820.745.821019.3
C30-0-0-927.153.39539.9
C30-0-1-1027.153.39631.6
C30-5-1-1127.153.39738.3
C30-5-2-1227.153.39867.1
C30-10-1-1327.153.39843.9
C30-10-2-1427.153.39950.3
C30-15-1-1527.153.39893.4
C30-15-2-1627.153.391069.8