Research Article

Influence of Microscopic Effects on the Static Tensile Strength of Gray Cast Iron HT200 Specimens

Table 1

Test values of extreme strength of gray cast iron HT200 specimens.

Specimen numberDiameter Φ(mm)Section area A(mm)2Extreme force Fb(kN)Extreme strength σb(MPa)

No. 17.6846.32489.82211.98
No. 27.8848.768912.34253.06
No. 38.0450.769510.35203.93
No. 48.252.810312.79242.19
No. 58.1452.040310.86208.61
No. 68.556.745213.41236.27
Mean value8.0751.243211.59226.01