Research Article
Influence of Microscopic Effects on the Static Tensile Strength of Gray Cast Iron HT200 Specimens
Table 1
Test values of extreme strength of gray cast iron HT200 specimens.
| Specimen number | Diameter Φ(mm) | Section area A(mm)2 | Extreme force Fb(kN) | Extreme strength σb(MPa) |
| No. 1 | 7.68 | 46.3248 | 9.82 | 211.98 | No. 2 | 7.88 | 48.7689 | 12.34 | 253.06 | No. 3 | 8.04 | 50.7695 | 10.35 | 203.93 | No. 4 | 8.2 | 52.8103 | 12.79 | 242.19 | No. 5 | 8.14 | 52.0403 | 10.86 | 208.61 | No. 6 | 8.5 | 56.7452 | 13.41 | 236.27 | Mean value | 8.07 | 51.2432 | 11.59 | 226.01 |
|
|