Research Article

Influence of Microscopic Effects on the Static Tensile Strength of Gray Cast Iron HT200 Specimens

Table 3

Calculated values of extreme strength of gray cast iron HT200 specimens.

Specimen numberDiameter Φ(mm)Initial microflaw size a0(mm)Test value σb(MPa)Calculated value σb(MPa)

No. 17.680.1236211.98211.90
No. 27.880.0711253.06253.00
No. 38.040.1422203.93203.90
No. 48.200.0808242.19242.20
No. 58.140.1309208.61208.60
No. 68.500.0870236.27236.30