Research Article

Numerical Simulation Analysis and Experimental Research on Damping Performance of a Novel Magnetic Fluid Damper

Table 2

The test results of harmonic forced vibration.

ConditionFrequency (Hz)Current (A)Amplitude (mm) (%)

Without damper9.34
TMFRBD11.7607.5119.59
TMFRBD21.7607.6018.63
TMFRBD11.7117.5119.59
TMFRBD21.711.17.5918.73
TMFRBD11.6627.6118.52
TMFRBD21.662.57.6917.67
TMFRBD11.6237.3121.73
TMFRBD21.623.67.4120.66
TMFRBD11.5747.4120.24
TMFRBD21.574.97.5619.06