Details of six design schemes.

Design schemeSegment ringThe pipe of heat exchangerConnection pipeMain conduit
NumberRadius (m)Exchanger typeqexchange (w/m2)Length (m)NumberLength (m)NumberLength(m)

TY-ET-3-air36.1Air18180220026
TY-ET-4-air46.1Air18180220028
TY-ET-3-ground36.1Ground source30180220026
TY-ET-4-ground46.1Ground source30180220028
TY-ET-3-air-ground36.1Dual36360220026
TY-ET-4-air-ground46.1Dual36360220028