Research Article

Analytical and Numerical Study of the Ground Pressure of the Work Face Crossing the Fault

Table 2

The contact pressure of upside and underside of the roof.

Fracture situationWork faceContact pressure of forward direction faultContact pressure of reverse direction fault
——Upside of roof (MPa)Underside of roof (MPa)Upside of roof (MPa)Underside of roof (MPa)

Without tunnel initial fractureFar5.1163.0199.8938.317
Near5.0443.62913.47117.895
Under0.0000.00014.25328.939
With tunnel initial fractureFar4.9243.6739.5798.379
Near4.8344.38613.10218.065
Under0.0000.00014.70728.555
Without tunnel periodical fractureFar6.0383.29410.7769.198
Near6.4094.07411.97214.234
Under4.2020.00013.14423.975
With tunnel periodical fractureFar5.8423.95810.5769.651
Near6.0235.10612.08215.556
Under3.5750.00013.37223.313