Research Article
Analysis of Multifactor Influence Model on Energy Dissipation Rate of Rough-Strips Energy Dissipator in the Spillway Bend
Table 2
Design of orthogonal test.
| | Test no. | h1 − h2/(cm) | ∆L/(cm) | θ/(rad) | Rc/(cm) | B/(cm) | Q/(L/s) |
| | 1 | 1.6–0.8 | 18 | 0.314 | 140 | 50 | 20 | | 2 | 1.6–0.8 | 24 | 0.384 | 170 | 60 | 22.5 | | 3 | 1.6–0.8 | 30 | 0.454 | 200 | 80 | 25 | | 4 | 2.0–1.0 | 18 | 0.314 | 170 | 60 | 25 | | 5 | 2.0–1.0 | 24 | 0.384 | 200 | 80 | 20 | | 6 | 2.0–1.0 | 30 | 0.454 | 140 | 50 | 22.5 | | 7 | 2.4–1.2 | 18 | 0.384 | 140 | 80 | 22.5 | | 8 | 2.4–1.2 | 24 | 0.454 | 170 | 50 | 25 | | 9 | 2.4–1.2 | 30 | 0.314 | 200 | 60 | 20 | | 10 | 1.6–0.8 | 18 | 0.454 | 200 | 60 | 22.5 | | 11 | 1.6–0.8 | 24 | 0.314 | 140 | 80 | 25 | | 12 | 1.6–0.8 | 30 | 0.384 | 170 | 50 | 20 | | 13 | 2.0–1.0 | 18 | 0.384 | 200 | 50 | 25 | | 14 | 2.0–1.0 | 24 | 0.454 | 140 | 60 | 20 | | 15 | 2.0–1.0 | 30 | 0.314 | 170 | 80 | 22.5 | | 16 | 2.4–1.2 | 18 | 0.454 | 170 | 80 | 20 | | 17 | 2.4–1.2 | 24 | 0.314 | 200 | 50 | 22.5 | | 18 | 2.4–1.2 | 30 | 0.384 | 140 | 60 | 25 |
|
|