Research Article
Analysis of Multifactor Influence Model on Energy Dissipation Rate of Rough-Strips Energy Dissipator in the Spillway Bend
| Test no. | B/(m) | hL/(m) | θ/(rad) | ∆L/(m) | 1/Re (×10−5) | 1/Fr2/(−) | η/(%) | k/(−) |
| 1 | 0.50 | 0.012 | 0.314 | 0.18 | 3.41 | 0.57 | 20.83 | 0.020 | 2 | 0.60 | 0.012 | 0.384 | 0.24 | 3.40 | 0.61 | 26.37 | 0.019 | 3 | 0.80 | 0.012 | 0.454 | 0.30 | 3.77 | 0.62 | 38.94 | 0.017 | 4 | 0.60 | 0.015 | 0.314 | 0.18 | 3.14 | 0.57 | 28.21 | 0.025 | 5 | 0.80 | 0.015 | 0.384 | 0.24 | 4.60 | 0.65 | 44.83 | 0.023 | 6 | 0.50 | 0.015 | 0.454 | 0.30 | 3.09 | 0.59 | 20.91 | 0.022 | 7 | 0.80 | 0.018 | 0.384 | 0.18 | 4.25 | 0.49 | 30.48 | 0.037 | 8 | 0.50 | 0.018 | 0.454 | 0.24 | 2.80 | 0.63 | 27.98 | 0.033 | 9 | 0.60 | 0.018 | 0.314 | 0.30 | 3.76 | 0.61 | 44.30 | 0.018 | 10 | 0.60 | 0.012 | 0.454 | 0.18 | 3.41 | 0.59 | 33.64 | 0.029 | 11 | 0.80 | 0.012 | 0.314 | 0.24 | 3.83 | 0.54 | 26.17 | 0.015 | 12 | 0.50 | 0.012 | 0.384 | 0.30 | 3.30 | 0.68 | 28.01 | 0.015 | 13 | 0.50 | 0.015 | 0.384 | 0.18 | 2.78 | 0.64 | 33.95 | 0.031 | 14 | 0.60 | 0.015 | 0.454 | 0.24 | 3.79 | 0.58 | 26.21 | 0.027 | 15 | 0.80 | 0.015 | 0.314 | 0.30 | 4.15 | 0.62 | 35.38 | 0.015 | 16 | 0.80 | 0.018 | 0.454 | 0.18 | 4.60 | 0.66 | 40.78 | 0.043 | 17 | 0.50 | 0.018 | 0.314 | 0.24 | 3.03 | 0.64 | 35.39 | 0.023 | 18 | 0.60 | 0.018 | 0.384 | 0.30 | 3.17 | 0.54 | 22.20 | 0.022 |
|
|