Research Article

Impact Damage Analysis of Fiber Reinforced Plastic Structure with Rib

Table 2

Test results I.

AngleMass (g)Energy (J)The body is cracked after 10 times testAngleMass (g)Energy (J)The body is crackedStrain pulse peak

90°131902/1045°131900/100.017
600/10600/100.008
300/10300/100.008
90901/1090900/100.025
601/10600/100.009
300/10300/100.003
67908/1067900/100.019
602/10600/100.011
300/10300/100.005
19905/1019900/100.017
600/10600/100.003
300/10300/100.003

Note: the strain range of the measuring instrument is −0.035∼0.035. It can be seen from the results in Table 3 that, under several test conditions, the shell was not damaged by the flying stone with small incident angle. When the incident angle was 90°, the shell was more likely to be damaged by the flying stone with medium and large mass. The large mass flying stone has a larger size and can contact at least two ribs at the moment of impact, so the impact energy is more dispersed. Even if the energy is larger, the shell cannot be completely damaged.