Research Article
Research on the Optimization of Automobile Plastic Front Frame Structure
Table 5
Static analysis information sheet.
| Load | Size (N) | Mounting point displacement (mm) | Maximum stress (MPa) | Design requirements (mm) | Does it meet the design requirements? |
| Locking limit pull | 5300 | 14.69 | 138 | 15 | Yes | Cushion impact | 1000 | 0.773 | 19.61 | 4 | Yes | Pedestrian impact | 5000 | 15.35 | 207.8 | 20 | Yes | Condenser support strength | 400 | 0.619 | 6.811 | 3 | Yes | Radiator support strength | 350 | 0.62 | 5.607 | 3 | Yes | Oil cooler mounting strength | 170 | 0.309 | 3.592 | 2 | Yes |
|
|