Research Article

Research on the Optimization of Automobile Plastic Front Frame Structure

Table 5

Static analysis information sheet.

LoadSize (N)Mounting point displacement (mm)Maximum stress (MPa)Design requirements (mm)Does it meet the design requirements?

Locking limit pull530014.6913815Yes
Cushion impact10000.77319.614Yes
Pedestrian impact500015.35207.820Yes
Condenser support strength4000.6196.8113Yes
Radiator support strength3500.625.6073Yes
Oil cooler mounting strength1700.3093.5922Yes