Research Article

[Retracted] Kinetics of Sludge Superheated Steam Drying and Optimization of Process Parameters

Table 3

Fitting results of restoration stage of sludge superheated steam drying under different drying conditions.

Fixed factor conditionVariable factor conditionModel coefficients k0R2χ2 ×10−6RMSE ×10−3

6 mm, 22 m3/h180°C−7.02597 × 10−40.99055.705182.39
195°C−8.00787 × 10−40.984377.707332.78
220°C−8.32655 × 10−40.975411.88853.45
260°C−9.16322 × 10−40.980185.186842.28

220°C, 22 m3/h2 mm−0.003010.9828317.31444.16
3.5 mm−0.001310.9445526.02875.1
6 mm−9.32495 × 10−40.988954.019672
10 mm−5.40755 × 10−40.9547911.60663.41

220°C, 6 mm22 m3/h−7.95143 × 10−40.987697.2812.7
29 m3/h−8.51206 × 10−40.9647214.26723.78
36 m3/h−8.0649 × 10−40.9167531.87075.65
40 m3/h−0.001110.961078.793752.97